Azure Application Gateway backend settings is somehow being overwritten. I changed it from 30 to 900 before and now it is back to 30

649 views Asked by At

In order to make my application specific tasks avoid timeout errors, inside AKS cluster, I have changed the backend settings of my azure application gateway "Request time-out (seconds)" from 30 to 900. However, it reverts back to be 30 when I check it next time. What can we do to make this timeout setting a permanent change.

Application Gateway Backend Settings

1

There are 1 answers

0
YK1 On BEST ANSWER

If you are using AGIC, you should control these settings from ingress annotations and not directly change it on application gateway.

You can use:

appgw.ingress.kubernetes.io/request-timeout: "900"

Reference: https://azure.github.io/application-gateway-kubernetes-ingress/annotations/#request-timeout