I'm trying to model a single queue, single server simulation using Simulink in MATLAB, I've recently installed it and I'm pretty new.
I've created a Time-Based Entity Generator (with an exponential arrival time), a FIFO queue with capacity of 50 entities and a Single Server with an exponential service time as shown in this image:
I wonder how I can count the number of entities that are generated but can't get into the FIFO because it's full (reached 50 entities already) and discard them.
This will probably not help you anymore, but I found a solution to this problem and thought I would share it for future reference. The way to solve it is using an Output Switch block with 2 ports. Connect the first to your FIFO queue and the second to a sink (or whatever you want your entities to go to) and select "First port that is not blocked" as a switching criterion. Picture here: https://i.stack.imgur.com/x8f6A.png. Cheers!