I am using ClearCase UCM - Multisite (version 7.x) When I rebase a partcular stream, I get following error.
cleartool Unable to determine modified elements in "<UUID>" in stream "<stream name>"
Advancing to baseline "temp2.6922" of component "cframework_src"
...
Updating rebase view's config spec...
Creating integration activity...
Setting integration activity...
Merging files...
cleartool: Error: Unable to determine modified elements in vob "14828f48.3c1411d6.a3a2.00:01:80:c3:ed:84" in stream "stream_name".
cleartool: Error: Unexpected error in rebase.
cleartool: Error: Unable to perform merge.
cleartool: Error: Unable to perform integration.
cleartool: Error: Unable to rebase stream "<stream_name>".
The magic uid somehow relate to a Vob family uuid-- listed below
Tag: \cframework_src
Global path: \\svr-inh-net-01\ccvobstore2\cframework_src.vbs
Server host: svr-inh-cc-02
Access: public
Mount options:
Region: MGI_WIN
Active: YES
Vob tag replica uuid: 510b4e21.ecef11df.8889.00:01:84:38:25:75
Vob on host: svr-inh-cc-02
Vob server access path: /project/ccvobstore2/cframework_src.vbs
Vob family uuid: 14828f48.3c1411d6.a3a2.00:01:80:c3:ed:84
Vob replica uuid: 510b4e21.ecef11df.8889.00:01:84:38:25:75
Vob registry attributes: replicated
What is the real maning of the error? How can I fix this?
More info
There are other streams which under same pvob. They all work fine. Sync is complete - no errors - anywhere.
What is puzzling is lack of information in error logs and clearcase logs.
This solution resolved the issue:
canceled the current rebase
After clearing the rebase, issued the following commands against
the branch type:
This repaired issues with the branch type.
After performing this step, issued "cleartool chstream -generate" or sycn the stream with the project from the GUI.